H301-diSPIM

The Okolab solution to enable long term experiments on ASI diSPIM set-up
 
Features:
  • Compatible with ASI diSPIM set-up
  • Operated by Okolab BOLD LINE temperature/gas/humidity controllers
  • It includes the specimen holder for 2"x3" inserts with rounded corners like the ASI I3078
  • Uniformly heated by means of embedded electric resistances both in the base and in the lid of the chamber
  • Collars for objectives in use, included
  • Quick opening chamber's design
  • Recommend humidity module: HM-ACTIVE
H301-diSPIM_480X320.jpg
H301-diSPIM
H301-diSPIM_420X280.jpg
H301-diSPIM

Koehler illumination ?

Remove the chamber riser and use the Koehler Lid

H301-diSPIM_components_420X280.jpg
H301-diSPIM components

Perfusion ?

Each chamber features up to 12 holes for inlet and outler of perfusion tubings

H301-diSPIM_EXPLODED_420X280.jpg
H301-diSPIM exploded view

Different sample holder ?

Change the chamber insert. It is a 5 seconds task with the magnetic sample holders

Keep the sample in the correct position by using the Magnetic Locks

 

 

 
 
 

H301-oSPIM

The Okolab solution to enable long term experiments on ASI oSPIM set-up.
 
Features:
  • Compatible with ASI oSPIM set-up
  • Operated by Okolab BOLD LINE temperature/gas/humidity controllers
  • It includes the specimen holder for 35mm Petri Dish
  • Uniformly heated by means of embedded electric resistances both in the base and in the lid of the chamber
  • Collar for objective in use, included
  • Recommend humidity module: HM-ACTIVE
H301-oSPIM_480X320.jpg
H301-oSPIM
H301-oSPIM_420X280.jpg
H301-oSPIM

Koehler illumination ?

Remove the chamber riser and use the Koehler Lid

H301-oSPIM_LID_420X280.jpg
H301-oSPIM lid and ojective adapter

Perfusion ?

Each chamber features up to 12 holes for inlet and outler of perfusion tubings

H301-oSPIM_EXPLODED_420X280.jpg
H301-oSPIM exploded view

Different sample holder ?

Change the chamber insert. It is a 5 seconds task with the magnetic sample holders

Keep the sample in the correct position by using the Magnetic Locks

 

 

 
 
 

H201-PRIOR-NZ500

Stage compatibility: screws onto Prior NZ250/400/500 - comes with Koelher lid
 
Magnetic interchangeable inserts allow to use:
  • 35/60 mm Petri
  • 1x3 in. / 1x2 in. chambered slides
  • 6-12-24-48-96 MW plates
Features:
  • Koelher lid for working under Koehler illumination
  • Optional lids available for Laser Safety, Injection during imaging
  • Flexible chamber height thanks to the removable chamber riser required to fit standard multiwell plates or to perform perfusion
  • Magnets allow easy interchange of chamber inserts
  • Magnetic locks hold Petri and Slides and MW in correct position inside the chamber
H201-PRIOR-NZ500_480x320.jpg
 

Available Inserts

H201-MW-HOLDER-NZ500 Multiwell plates holder /H201-MW-HOLDER_600x600.JPG
1x35-M #1 35mm Petri-dish 1x35-M.JPG
1x35-PRIOR-NZ500 #1 35mm Petri-dish 1x35-PRIOR-NZ500.JPG
1xGS-PRIOR-N-NZ500 #1 1x3in. chamberslide 1xGS-PRIOR-NZ500.JPG
1xLABTEK-PRIOR-NZ500 #1 Lab-Tek 1x2 in. chambered cover glass 1xLABTEK-PRIOR-NZ500.JPG
1xLABTEK-II-PRIOR-NZ500 #1 Lab-Tek II 1x2 in. chambered cover glass 1xLABTEK-II-PRIOR-NZ500.JPG
1x60-PRIOR-NZ500 #1 60mm Petri-dish 1x60-PRIOR-NZ500.JPG
1xT25-PRIOR-NZ500 #1 Nunc and Greiner T25 flask 1xT25-PRIOR-NZ500.JPG
2x35-PRIOR-NZ500 #2 35mm Petri-dish 2x35-PRIOR-NZ500.JPG
2xGS-PRIOR-NZ500 #2 1x3in. chamberslides 2xGS-PRIOR-NZ500.JPG
2xLABTEK-PRIOR-NZ500 #2 Lab-Tek 1x2 in. chambered cover glass 2xLABTEK-PRIOR-NZ500.JPG
2xLABTEK-II-PRIOR-NZ500 #2 Lab-Tek II 1x2 in. chambered cover glass 2xLABTEK-II-PRIOR-NZ500.JPG
2x60-PRIOR-NZ500 #2 60mm Petri-dish 2x60-PRIOR-NZ500.JPG
4x35-PRIOR-NZ500 #4 35mm Petri-dish 4x35-PRIOR-NZ500.JPG
GS35-PRIOR-NZ500 #1 1x3in. chamberslide and #2 35mm Petri-dish GS35-PRIOR-NZ500.JPG
LABTEK-35-PRIOR-NZ500 #1 Lab-Tek 1x2 in. chambered cover glass and #2 35mm Petri-dish LABTEK-35-PRIOR-NZ500.JPG
LABTEK-II-35-PRIOR-NZ500 #1 Lab-Tek II 1x2 in. chambered cover glass and #2 35mm Petri-dish LABTEK-II-35-PRIOR-NZ500.JPG
LABTEK-60-PRIOR-NZ500 #1 Lab-Tek 1x2 in. chambered cover glass and #1 60mm Petri-dish LABTEK-60-PRIOR-NZ500.JPG
LABTEK-II-60-PRIOR-NZ500 #1 Lab-Tek II 1x2 in. chambered cover glass and #1 60mm Petri-dish LABTEK-II-60-PRIOR-NZ500.JPG
GS60-PRIOR-NZ500 #1 1x3in. chamberslide and #1 60mm Petri-dish GS60-PRIOR-NZ500.JPG
6035-PRIOR-NZ500 #1 60mm Petri-dish and #1 35mm Petri-dish 6035-PRIOR-NZ500.JPG

Available LIDs

H201-KOEHLER-LID-PRIOR-NZ500 Glass lid that reduces the height of the chamber to 22 mm.It allows to work under Koehler illumination. H201-MW-LOCK-22.5.JPG
H201-INJECTION-LID-PRIOR-NZ500 Glass lid with two small openings (sealed with flexible plastic) to allow injection or permanent access to the specimen. Note: compatible only with specimen holder 1x35 H201-MW-LOCK-22.5.JPG
H201-LASER-INTERLOCK-LID-PRIOR-NZ500 Glass lid with a safety switch that connects to the laser box. The switch turns off the laser, when the lid is lifted Note: compatible only with specimen holder 1x35 H201-MW-LOCK-22.5.JPG
H201-PRIOR-NZ500-[KOEHLER-LID]_600x600.jpg
H201-PRIOR-NZ500 with Koehler Lid
H201-PRIOR-NZ500-LID_600x600.jpg
H201-PRIOR-NZ500 - Available Lids
H201-PRIOR-NZ500-[KOEHLER-LID]-[DIMENSIONS]_600x600.jpg
H201-PRIOR-NZ500 - Dimensions
H201-PRIOR-NZ500-[ADAPTERS-2]600x600.jpg
H201-PRIOR-NZ500 - Magnetic Inserts
H201-PRIOR-NZ500-[ADAPTERS]_600x600.jpg
H201-PRIOR-NZ500 - Magnetic Inserts
H201-K-FRAME-MAGNETIC-LOCKS.jpg
H201-PRIOR-NZ500 - Magnetic sample locks
 
 
 

H201-UP

Stage compatibility: fits on Upright Microscopes
  • Part number of the objectives in use must be specified in purchase order
  • XY stage model and serial number must be specified in purchase order
The chamber can fit:
  • 35/60 mm Petri
  • 1x3 in. / 1x2 in. chambered slides
Features:
  • Suitable for dipping lens
  • Manageable chamber thanks to the opening of the lid to introduce the objective
  • Magnets allow easy interchange chamber insert
  • Magnetic locks hold Petri, Slides in correct position inside the chamber
  • Perfusion holes: 12 channels for 2.0 mm O.D. tubings are available
  • To control the humidity into the chamber humidity module is recommended: HM-ACTIVE

 

H201-UP_480x320.jpg

Available Inserts

UP-1x35-M #1 35mm Petri-dish UP-1x35-M.JPG
UP-1xGS-M #1 1x3 in. chamber slide UP-1xGS-M.JPG
UP-1xLABTEK-M #1 Lab-Tek 1x2 in. chambered cover glass UP-1xLABTEK-M.JPG
UP-1xLABTEK-II-M #1 Lab-Tek II 1x2 in. chambered cover glass UP-1xLABTEK-II-M.JPG
UP-1x60-M #1 60mm Petri-dish UP-1x60-M.JPG

Available Drawings

H201-UP-[Exploded-OPEN]_600x600.jpg
H201-UP - Components
H201-UP-[ADAPTERS-1]_600X600.jpg
H201-UP - Available inserts 
H201-UP-[LID-STANDARD]-[DIMENSIONS]_600x600.jpg
H201-UP - Dimensions
 

H201-PRIOR-NZ100-H117

Stage compatibility: fits on Prior NZ100/200 in Prior H117
 
The chamber can fit:
  • 35/60 mm Petri
  • 1x3 in. chambered slides
  • No insert is required
Features:
  • The chamber hosts #1 35mm petri or #1 chamber slide
  • Flexible chamber height thanks to the removable chamber riser required to perform perfusion
  • Perfusion holes: 12 channels for 2.5mm O.D. tubings are available in chamber riser

 

 

H201-PI-P-736-ZR1S-ZR2S_480x320.jpg

Available Drawings

H201-PRIOR-NZ100-H117_600x600 (2).jpg
H201-PRIOR-NZ100-H117 - 3D View
H201-PRIOR-NZ100-H117_600x600.jpg
H201-PRIOR-NZ100-H117 - Components
H201-PRIOR-NZ100-H117-[DIMENSIONS]_600x600.jpg
H201-PRIOR-NZ100-H117 - Dimensions 
 

COPYRIGHT © OKOLAB S.R.L. ALL RIGHT RESERVED. CERTIFIED ISO 9001.